Finished white plastic color specification
| Parameter | Write in the approval record |
|---|---|
| Reference and specimen | Master ID and revision, material, texture and measured thickness |
| Instrument conditions | Geometry, aperture, mode, illuminant, observer, backing and preparation |
| Sampling plan | Which parts, locations, repetitions and averaging rule |
| Color decision | Named ΔE formula, tolerance, required coordinate limits and retest procedure |
| Separate appearance tests | Secondary-light check, visible defects and relevant opacity criterion |
Convert an approved reference into a measurement record
Assign the master sample an ID and a revision. Select the actual acceptance surface and defined measurement zones. Keep a retained copy or an agreed documented replacement. Specify sample thickness, texture, orientation and backing where these can affect the readings. For thin, light-transmitting specimens, agree how the backing and specimen preparation will be controlled.
Write down the settings attached to the number
Have the lab record the instrument, measurement geometry, aperture, illuminant and observer. For instrument modes that include or exclude specular reflection, record the selected mode. Define sample count, measurement locations, conditioning and averaging rules. Buyer and supplier can compare readings on the same reference and a trial sample before approving the full batch.
Name the ΔE formula and preserve the color direction
ΔE expresses the size of a color difference. CIEDE2000 is commonly written ΔE00 and is a different formula from CIELAB ΔE*ab. Record the exact formula and any agreed parameters. For sample minus reference, lower L* is darker and positive Δb* shifts toward yellow. As an illustrative coordinate example, reference L* 95.4, a* 0.1, b* 1.1 and sample L* 95.0, a* 0.0, b* 1.7 give ΔL* −0.4 and Δb* +0.6. These are component differences, and the example supplies no tolerance.
Define borderline results and visible mismatch
Agree the limit and whether it applies to each zone or to a specified statistic. Ask who retests a borderline result and which retained reference to use. If samples agree under one light and separate under a required secondary light, record the observation and apply the agreed second-light protocol. For relevant uses, retain visual checks of texture or streaks and an independent opacity check.
Issue one approval record to buyer, supplier and plant
List the exact resin, white grade, sample lot, actual dose, location values, difference formula, approved settings and disposition. Use this record for the first order and when a change requires another trial. The baseline supports repeatability and lets both sides investigate shade drift using the same geometry and method.
Common questions
What ΔE tolerance should I put on a white masterbatch purchase order?
Use a buyer-approved tolerance for the finished use, specified with the formula, instrument settings and decision rule. A single number without those conditions cannot settle a disagreement.
Does a small ΔE prove equal opacity?
Use color difference to evaluate shade under the agreed conditions. If the product also must hide its contents or backing, apply the separately agreed opacity or transmission method.